FieldTalk Modbus Slave C++ Library
Library version 2.9.1
|
Base class for all IP based Slave Protocol classes. More...
Public Member Functions | |
MbusIpServerBase () | |
Constructs a MbusIpServerBase object and initialises its data. | |
int | addDataTable (int slaveAddr, MbusDataTableInterface *dataTablePtr) |
Associates a protocol object with a Data Provider and a Modbus slave ID. More... | |
int | getConnectionStatus () |
Checks if a Modbus master is polling periodically. More... | |
Static Public Member Functions | |
static const TCHAR * | getPackageVersion () |
Returns the library version number. More... | |
Protocol Configuration | |
int | setTimeout (long timeOut) |
Configures master activity time-out supervision. More... | |
long | getTimeout () |
Returns the currently set master activity time-out value. More... | |
void | disableExceptionReplies () |
Supress exception replies to be sent. More... | |
void | enableExceptionReplies () |
Enables exception replies after they have been turned off. More... | |
Transmission Statistic Functions | |
unsigned long | getTotalCounter () |
Returns how often a message transfer has been executed. More... | |
void | resetTotalCounter () |
Resets total message transfer counter. | |
unsigned long | getSuccessCounter () |
Returns how often a message transfer was successful. More... | |
void | resetSuccessCounter () |
Resets successful message transfer counter. | |
TCP/IP Server Management Functions | |
virtual int | startupServer () |
Puts the Modbus server into operation. More... | |
virtual int | startupServer (const char *const hostName)=0 |
virtual void | shutdownServer () |
Shuts down the Modbus server. More... | |
virtual int | serverLoop ()=0 |
Modbus slave server loop. More... | |
int | isStarted () |
Returns whether server has been started up. More... | |
int | setPort (unsigned short portNo) |
Sets the TCP port number to be used by the protocol. More... | |
void | installIpAddrValidationCallBack (int(*f)(const char *masterIpAddrSz)) |
This function installs a callback handler for validating a master's IP address. More... | |
void | installMasterPollNotifyCallBack (void(*f)(const char *masterIpAddrSz)) |
This function installs a callback handler to be called everytime a master polls this slave. More... | |
unsigned short | getPort () |
Returns the TCP port number used by the protocol. More... | |
Base class for all IP based Slave Protocol classes.
This class is a base class for the various flavours of IP based protocols.
|
virtual |
Puts the Modbus server into operation.
The server accepts connections on any interface.
This function opens a TCP/IP socket, binds the configured TCP port to the Modbus/TCP protocol and initialises the server engine.
Reimplemented in MbusTcpSlaveProtocol, and MbusUdpSlaveProtocol.
|
virtual |
Shuts down the Modbus server.
This function closes all TCP/IP connections to MODBUS/TCP masters and releases any system resources associated with the connections.
Implements MbusSlaveServer.
Reimplemented in MbusTcpSlaveProtocol, and MbusUdpSlaveProtocol.
|
pure virtual |
Modbus slave server loop.
This server loop must be called continuously. It must not be blocked. The server has to be started before calling the serverLoop() method.
In most cases the server loop is executed in an infinite loop in its own thread:
Implements MbusSlaveServer.
Implemented in MbusTcpSlaveProtocol, MbusRtuOverTcpSlaveProtocol, and MbusUdpSlaveProtocol.
|
virtual |
Returns whether server has been started up.
true | = started |
false | = shutdown |
Implements MbusSlaveServer.
int setPort | ( | unsigned short | portNo | ) |
Sets the TCP port number to be used by the protocol.
portNo | Port number the server shall listen on |
FTALK_SUCCESS | Success |
FTALK_ILLEGAL_STATE_ERROR | Server already running |
References FTALK_ILLEGAL_STATE_ERROR, FTALK_SUCCESS, and isStarted().
void installIpAddrValidationCallBack | ( | int(*)(const char *masterIpAddrSz) | f | ) |
This function installs a callback handler for validating a master's IP address.
Pass a pointer to a function with checks a master's IP address and either accepts or rejects a master's connection.
f | Callback function pointer |
void installMasterPollNotifyCallBack | ( | void(*)(const char *masterIpAddrSz) | f | ) |
This function installs a callback handler to be called everytime a master polls this slave.
This routine can be used to implement custom time-out mechanisms.
f | Callback function pointer |
|
inline |
Returns the TCP port number used by the protocol.
|
inherited |
Associates a protocol object with a Data Provider and a Modbus slave ID.
slaveAddr | Modbus slave address for server to listen on (-1 - 255). 0 is regarded as a valid value for a MODBUS/TCP server address. A value of -1 means the server disregards the slave address and listens to all slave addresses. 0 or -1 is only valid for MODBUS/TCP! |
dataTablePtr | Modbus data table pointer. Must point to a Data Provider object derived from the MbusDataTableInterface class. The Data Provider is the interface between your application data and the Modbus network. |
References FTALK_ILLEGAL_ARGUMENT_ERROR, and FTALK_SUCCESS.
|
inlineinherited |
Checks if a Modbus master is polling periodically.
true | = A master is polling at a frequency higher than the master transmit time-out value |
false | = No master is polling within the time-out period |
|
inherited |
Configures master activity time-out supervision.
The slave can monitor whether a master is actually polling or not. This function sets the activity time-out to the specified value. A value of 0 disables the time-out, which stops time-out notifications being sent to the Data Provider. Default value is 1000 ms.
timeOut | Timeout value in ms (Range: 0 - 100000), 0 disables time-out |
FTALK_SUCCESS | Success |
FTALK_ILLEGAL_ARGUMENT_ERROR | Argument out of range |
References FTALK_ILLEGAL_ARGUMENT_ERROR, and FTALK_SUCCESS.
|
inlineinherited |
Returns the currently set master activity time-out value.
|
inherited |
Supress exception replies to be sent.
With this option only positive replies are sent to the master. All failure replies are silently discarded. This option can be useful if redundant Modbus devices are used. In this scenario supressing the reply would trigger a swap-over of the redundant devices.
|
inherited |
Enables exception replies after they have been turned off.
Sending exception replies in case of slave failures is the normal mode of operation.
|
inlineinherited |
Returns how often a message transfer has been executed.
|
inlineinherited |
Returns how often a message transfer was successful.
|
staticinherited |
Returns the library version number.