MbusMasterFunctionswriteMultipleMod10000 Method (Int32, Int32, Int32, Int32) |
Namespace: FieldTalk.Modbus.Master
public int writeMultipleMod10000( int slaveAddr, int startRef, int[] int32Arr, int numRegs )
Public Function writeMultipleMod10000 ( slaveAddr As Integer, startRef As Integer, int32Arr As Integer(), numRegs As Integer ) As Integer
public: int writeMultipleMod10000( int slaveAddr, int startRef, array<int>^ int32Arr, int numRegs )
Note |
---|
Modbus does not know about any other data type than discretes and 16-bit registers. Because a modulo-10000 value is of 32-bit length, it will be transferred as two consecutive 16-bit registers. This means that the amount of registers transferred with this function is twice the amount of int values passed to this function. |
Note |
---|
Broadcast supported for serial protocols |