MbusMasterFunctions Class |
Namespace: FieldTalk.Modbus.Master
The MbusMasterFunctions type exposes the following members.
Name | Description | |
---|---|---|
pollDelay | Poll delay property | |
retryCnt | Retry count property | |
timeout | Time-out port property |
Name | Description | |
---|---|---|
closeProtocol | Closes an open protocol including any associated communication
resources (COM ports or sockets). | |
configureBigEndianInts | Configures 32-bit int data type functions to do a word swap | |
configureBigEndianInts(Int32) | Configures 32-bit int data type functions to do a word swap
on a per slave basis | |
configureCountFromOne | Configures the reference counting scheme to start with one for
all slaves. | |
configureCountFromOne(Int32) | Configures the reference counting scheme to start with one for
a slave. | |
configureCountFromZero | Configures the reference counting scheme to start with
zero for all slaves. | |
configureCountFromZero(Int32) | Configures the reference counting scheme to start with
zero for a slave. | |
configureEnron32BitMode | Configures all slaves for Daniel/ENRON 32-bit Mode. | |
configureEnron32BitMode(Int32) | Configures a slave for Daniel/ENRON 32-bit Mode. | |
configureIeeeFloats | Configures float data type functions NOT to do a word swap | |
configureIeeeFloats(Int32) | Configures float data type functions NOT to do a word swap
on a per slave basis | |
configureLittleEndianInts | Configures 32-bit int data type functions NOT to do a word swap | |
configureLittleEndianInts(Int32) | Configures 32-bit int data type functions NOT to do a word swap
on a per slave basis | |
configureStandard32BitMode | Configures all slaves for Standard 32-bit Mode. | |
configureStandard32BitMode(Int32) | Configures a slave for Standard 32-bit Mode. | |
configureSwappedFloats | Configures float data type functions to do a word swap | |
configureSwappedFloats(Int32) | Configures float data type functions to do a word swap
on a per slave basis | |
customFunction | User Defined Function Code | |
Dispose | Releases any associated communication resources (serial ports or sockets). | |
forceMultipleCoils(Int32, Int32, Boolean) | Modbus function 15 (0F hex), Force Multiple Coils. | |
forceMultipleCoils(Int32, Int32, Boolean, Int32) | Modbus function 15 (0F hex), Force Multiple Coils. | |
getPackageVersion | Returns the package version number. | |
getPollDelay | Returns the poll delay time | |
getRetryCnt | Returns the automatic retry count | |
getSuccessCounter | Returns how often a message transfer was successful | |
getTimeout | Returns the current time-out setting | |
getTotalCounter | Returns how often a message transfer has been executed | |
isOpen | Returns whether the protocol is open or not. | |
maskWriteRegister | Modbus function 22 (16 hex), Mask Write Register. | |
readCoils(Int32, Int32, Boolean) |
Modbus function 1 (01 hex),
Read Coil Status/Read Coils.
| |
readCoils(Int32, Int32, Boolean, Int32) |
Modbus function 1 (01 hex),
Read Coil Status/Read Coils.
| |
readDeviceIdentification | Modbus function 43 (hex 2B) subfunction 14 (hex 0E), Read Device Identification | |
readExceptionStatus | Modbus function 7 (07 hex), Read Exception Status. | |
readFileRecord(Int32, MbusMasterFunctionsFileSubRequest) |
Modbus function 20, Read File Record.
| |
readFileRecord(Int32, Int32, Int32, Int32, Int16) |
Modbus function 20, Read File Record.
| |
readInputDiscretes(Int32, Int32, Boolean) |
Modbus function 2 (02 hex),
Read Inputs Status/Read Input Discretes.
| |
readInputDiscretes(Int32, Int32, Boolean, Int32) |
Modbus function 2 (02 hex),
Read Inputs Status/Read Input Discretes.
| |
readInputMod10000(Int32, Int32, Int32) | Modbus function 4 (04 hex) for 32-bit modulo-10000 long int data types,
Read Input Registers as modulo-10000 long int data. | |
readInputMod10000(Int32, Int32, Int32, Int32) | Modbus function 4 (04 hex) for 32-bit modulo-10000 long int data types,
Read Input Registers as modulo-10000 long int data. | |
readInputRegisters(Int32, Int32, Array) |
Modbus function 4 (04 hex),
Read Input Registers (16-bit, 32-bit, 64-bit and floating point single and double).
| |
readInputRegisters(Int32, Int32, Array, Int32) |
Modbus function 4 (04 hex),
Read Input Registers (16-bit, 32-bit, 64-bit and floating point single and double).
| |
readMultipleMod10000(Int32, Int32, Int32) |
Modbus function 3 (03 hex) for 32-bit modulo-10000 long int data types,
Read Holding Registers/Read Multiple Registers as modulo-10000 long int
data.
| |
readMultipleMod10000(Int32, Int32, Int32, Int32) |
Modbus function 3 (03 hex) for 32-bit modulo-10000 long int data types,
Read Holding Registers/Read Multiple Registers as modulo-10000 long int
data.
| |
readMultipleRegisters(Int32, Int32, Array) |
Modbus function 3 (03 hex),
Read Holding Registers (16-bit, 32-bit, 64-bit and floating point single and double).
| |
readMultipleRegisters(Int32, Int32, Array, Int32) |
Modbus function 3 (03 hex),
Read Holding Registers (16-bit, 32-bit, 64-bit and floating point single and double).
| |
readWriteRegisters(Int32, Int32, Int16, Int32, Int16) | Modbus function 23 (17 hex), Read/Write Registers. | |
readWriteRegisters(Int32, Int32, Int16, Int32, Int32, Int16, Int32) | Modbus function 23 (17 hex), Read/Write Registers. | |
resetSuccessCounter | Resets successful message transfer counter | |
resetTotalCounter | Resets total message transfer counter | |
restartCommunicationsOption | Modbus function code 8, sub-function 01, Restart Communications Option | |
returnQueryData | Modbus function code 8, sub-function 00, Return Query Data. | |
setPollDelay | Poll delay property | |
setRetryCnt | Configures the automatic retry setting | |
setTimeout | Configures time-out | |
writeCoil | Modbus function 5 (05 hex), Force Single Coil/Write Coil. | |
writeFileRecord(Int32, MbusMasterFunctionsFileSubRequest) |
Modbus function 21, Write File Record.
| |
writeFileRecord(Int32, Int32, Int32, Int32, Int16) |
Modbus function 21, Write File Record.
| |
writeMultipleMod10000(Int32, Int32, Int32) |
Modbus function 16 (10 hex) for 32-bit modulo-10000 long int data types,
Preset Multiple Registers/Write Multiple Registers with
modulo-10000 long int data.
| |
writeMultipleMod10000(Int32, Int32, Int32, Int32) |
Modbus function 16 (10 hex) for 32-bit modulo-10000 long int data types,
Preset Multiple Registers/Write Multiple Registers with
modulo-10000 long int data.
| |
writeMultipleRegisters(Int32, Int32, Array) |
Modbus function 16 (10 hex),
Write Multiple Registers (16-bit, 32-bit, 64-bit and floating point single and double).
| |
writeMultipleRegisters(Int32, Int32, Array, Int32) |
Modbus function 16 (10 hex),
Write Multiple Registers (16-bit, 32-bit, 64-bit and floating point single and double).
| |
writeSingleRegister(Int32, Int32, Int16) |
Modbus function 6 (06 hex),
Preset Single Register/Write Single Register.
| |
writeSingleRegister(Int32, Int32, UInt16) |
Modbus function 6 (06 hex),
Preset Single Register/Write Single Register.
|